Maximum Destruction Rate

Thermal Oxidizers operate by Three T’s; Time, Temperature, and Turbulence. By heating a chamber to a temperature between 1400°F and 1800°F and then mixing the waste gases with air, the mixture resides in the chamber for sufficient time to decompose the gases into inerts such as water and carbon dioxide.

The HERO Process Solutions Thermal Oxidizer can guarantee a 99% – 99.9% DRE and are 40 CFR 60.18 compliant.

By utilizing the heat of the waste gas and controlling the amount of air going into the chamber, HERO’s Thermal Oxidizers can significantly reduce the amount of assist gas needed, up to 30% compared with regular flare consumption.

standard features

  • 99% or greater destruction rate efficiency
  • Unlimited turndown
  • Ceramic lined stack
  • Temperature controlled
  • Automated BMS w/ PLC
  • Pilot system accessible from outside the Thermal Oxidizer
  • Flame arrestor
  • High-temperature shutdown